Skip to main content

Mitigating Risks from Gas Releases with CAPEX and OPEX Considerations

DID YOU KNOW?

The success rate of a gas detection system to detect gas releases in known incidences is only about 60%*.

The effectiveness of the safety shutdown system to mitigate risks arising out of accidental gas releases is highly dependent on the associated gas detection system's ability to reliably detect gas releases, and to detect it quickly. Modern gas detection technologies are now available to help you improve the success rate of gas detection.

Speak to our specialists to understand how MSA's latest gas detection technologies can help you reduce the risks that you face each day.

Speak to MSA Specialist Today

*Source: HSE UK Statistics - Offshore Hydrocarbon Releases Statistics 2000 (HSE Report # OTO 2000 112).

Choose Your Best Defense, Apply Layers of Detection with MSA

No single detection technology can mitigate completely the risks arising out of accidental gas releases.

(1) Ultrasonic Gas Leak Detector | (2) Open Path Gas Detector | (3) New Generation Point Detector | (4) Flame Detector | (5) Portable Gas Detectors

Having multiple layers of detection, is presently the best defense against these risks.

MSA has a very complete range of gas detection technologies, each well suited for detecting a different stage of gas release. This is complemented by a good range of flame detectors, gas and flame mapping tools, safety rated controllers and in-house integration capabilities. We have a very complete solution to protect customers from the risks caused by accidental gas releases.

Learn more on MSA Gas Detection: Layered Gas & Flame Monitoring »


New Generation Point Detector

Learn More

Open Path Gas Detector

Learn More

Ultrasonic Gas Leak Detector

Learn More

Flame Detector

Learn More

System Controller Custom Product

Learn More

Risk Reduction Delivers Better Capital Resources Allocation and Better Protection

Be Better Protected Against…

The gas and flame detection system is put in place to reduce the consequence of gas explosions and fires. Consequences could include one or more of the following:

  • Capital loss due to infrastructure damage
  • Serious injury or loss of life
  • Production loss due to process shutdowns
  • Environmental contamination
  • Lawsuits

The biggest factor that limits the effectiveness of any gas detection system is Detection Coverage. If the system is unable to detect the gas (i.e. "cover"), then it would not know when to execute the needed safety actions. Detection Coverage is therefore crucial.

Challenge of Risk Reduction

Almost all gas detection technologies need the gas to 'arrive' at the detector (or detection line) in order for detection to occur. In reality, positioning gas detectors to ensure that a high likelihood of this happening is an engineering challenge, especially for outdoor process areas. Mechanical obstructions, area congestion due to equipment and piping, release mechanisms, direction of release, impingement, relative density of the released gas and wind influence, are all factors that influence the behavior of gas plumes and make detector placement a very difficult task for the engineer.

Improving Detection Effectiveness

It is common these days, to find the engineer relying on software tools (i.e. gas dispersion modelling, gas and flame mapping) to help determine detector positions by simulating the behavior of gas releases and the resulting plumes. While there has been significant advances of such tools, a good measure of design assumptions supported by engineering experience is usually still needed. What this means is, a degree of uncertainty often remains. The engineer can attempt to reduce this uncertainty by making more safety conservative assumptions. But a more conservative approach in favor of safety, may also result in a greater number of detectors (i.e. higher CAPEX) and a corresponding increase in maintenance (i.e. higher OPEX). In this era of cost cutting and restraining, this is likely to be a difficult balancing act.

Solutions by MSA

An understanding of different gas detection technologies and its suitability for detecting at different stages of release can make a difference. It is possible to improve detection effectiveness without an excessive increase in detector quantity. This means CAPEX (and OPEX) can be restrained, even when a more safety conservative approach is preferred.

Find out more from MSA Gas Detection Systems Comparison Report on how different detection technologies perform for each consideration of Risk Reduction, CAPEX, and OPEX.

If you wish to speak to our specialists to understand how MSA's latest gas detection technologies can help you reduce the risks that you face each day, request for a consultation today.

Case Study

Open Path Gas Detector

Application Notes

Oil, Gas and Petrochemical

Industrial

Wastewater

Custom Gas Sampling/Flow Panels

Whitepapers

2016-2017 Gas Detection Seminars
Mitigating risks from gas releases with CAPEX and OPEX considerations

The effectiveness of the gas detection system to reliably detect unintentional gas releases quickly is crucial for the mitigation of flammable gas explosion risks or toxic gas poisoning risks. The selection of detection methods and strategic siting of detectors are critical engineering decisions that impact system effectiveness. Since such decisions have CAPEX and OPEX implications, asset owners would benefit by applying newer detection technologies, that are not only more effective but offer also significant cost savings over time.

2017-2018 Gas Detection Seminars
Practicable approaches to mitigate risks from flammable and toxic gas releases... with CAPEX and OPEX considerations

The ability of the gas detection system to detect gas releases reliably and quiickly is crutial for the mitigation of flammable gas explosion risks or toxic gas poisoning risks. Deciding detector placements for good detection coverage that will ensure fast alarming of gas releases is therefore a critical task for the gas detection system engineer. This task is significantly more difficult when the area to be monitored is an open space that is subjected to changes of wind speed and direction. Having to balance between risk mitigation and cost considerations further complicates this task.

Find out more »

Date Location Audience Status
Feb 14, 2017 Bangkok, Thailand PTTEP, Chevron, Coastal Energy, Technip Engineering, IQS, Pol Dhanya Closed
Feb 16, 2017 Pattaya, Thailand Thai Oil Closed
Mar 7, 2017 Kerteh, Malaysia Petronas, Armada Engineering Closed
Mar 9, 2017 Kuala Lumpur, Malaysia Petronas, AMEC, Akers, DialogAsia, Technip, SBM, Petrofac, Repsol Closed
May 16 - 18, 2017 Singapore MSA Associates & Technical Partners Closed
May 11, 2017 Singapore Ministry of Manpower Closed
Next Seminar Date TBC Next Seminar Location TBC Safety Engineers / Process Safety Engineers, Plant Safety Managers, FGS Consultants / Specialists Register Now

Download Seminar Flyer
Register Your Interest

Multimedia

Fixed Gas and Flame Detection

MSA UltraSonic EX-5 Gas Leak Detector

Fire and Gas Mapping

MSA ALTAIR® 5X Portable Multigas Detector

MSA Ultima MOS-5 Hydrogen Sulfide Detector

MSA FlameGard® 5 Series Flame Detectors

Ultima OPIR-5 Open Path Infrared Gas Detector

MODEL 10K Integrated Fire and Gas System

MSA Ultima X Series Gas Detection Monitors

MSA XCell Sensor Gas Detection Technology

MSA SafEye™ 800 Open-Path Combustible Gas Detection System

MSA Permanent Gas Monitoring System Custom Products

MSA SUPREMATouch Controller

FlameGard® MSIR & UV/IR Performance Comparison and Test Lamp How-to

MSA GasGard XL Controller

Your One-Stop Service for All Your Gas Detection Needs

Download Comparison Report Register Interest for Seminar Speak to MSA Specialist Today